4…20 mA output signal + HART 5 / HART 7 protocol (special version: 0…20 mA or 0…5 mA output signal + HART 5 protocol)
Display with backlight
Safety version SIL2/SIL3
Intrinsic safety certificate ATEX, IECEx, FM, CSA(FM), INMETRO
Explosion proof certificate ATEX, IECEx, FM, CSA(FM), INMETRO
Programmable zero range, shift, characteristic and damping ratio with local panel keys
Static pressure limit up to 700bar
Accuracy 0,075% (0,05%, 0,04% on request)
Marine certificate – DNV, BV
Gold plated diaphragms
Wetted parts material 316L/Hastelloy C276
4…20 mA output signal + HART protocol
ATEX Intrinsic safety
Static pressure limit up to 320 bar
Accuracy 0.1%
Wetted parts material 316L
4…20 mA output signal + HART protocol
Intrinsic safety certificate (ATEX, IECEx)
Static pressure limit up to 420 bar
Accuracy 0,1%
Wetted parts material Hastelloy C276
Marine certificate DNV, BV
Digital communication protocol Modbus RTU
Intrinsic safety and explosion proof certificates (ATEX, IECEx)
Accuracy 0.1%
Static pressure limit up to 413 bar
Marine certificate DNV, BV
Overloads up to 420 bar total static pressure
Accuracy 0,25%
Any range from 0…16 mbar up to 0…25 bar
Intrinsic safety certificate (ATEX, IECEx)
Marine certificate – DNV, BV
Accuracy 0.4%
Measuring ranges: 0 ÷ 1, 0 ÷ 2.5, 0 ÷ 4 bar; 0 ÷ 6, 0 ÷ 10 bar; 0 ÷ 16, 0 ÷ 25 bar
Output signal 4 ÷ 20 mA or 0 ÷ 10 V
Process connection: M20x1,5, 1/4”NPTF
Smart or analog differential pressure transmitters with diaphragm seals for level measurement to pressure tank with gas-filled negative pressure line are recommended transmitters with diaphragm seal mounted on "+" side to pressure tank with liquid-filled negative line are recommended transmitters with diaphragm seal mounted on "-" side and converted output signal.
More information -> 4...20 mA output signal + HART 5 / HART 7 protocol
Accuracy 0,1%
Safety version SIL2/SIL3
Intrinsic safety certificate ATEX, IECEx, FM, CSA (FM), INMETRO
Explosion proof certificate ATEX, IECEx, FM, CSA (FM), INMETRO
Fully welded sensor guarantees tightness of oil system for many years
Ability to configure measuring range locally
Measurement of differential pressure based on two absolute pressure transmitters
Modular construction with posibility of replacing of each module of the measuring system
Output signal 4 ÷ 20 mA + HART
Accuracy 0,1%